top of page

Pure Water membrane - PWN Overview

I'm a paragraph. Click here to add your own text and edit me. It's easy.

The PWM reverse osmosis membrane is engineered for superior water purification and high-efficiency performance in a variety of demanding applications, including industrial water treatment and desalination processes.

 

the PWM membrane incorporates advanced technology, providing exceptional contaminant rejection and a high permeate flow rate. Designed to function optimally under diverse operational conditions, the PWM membrane offers excellent performance across a broad pressure range and temperature spectrum. Its robust construction and extensive chemical compatibility make it a reliable choice for systems requiring high-quality permeate and long-term durability.

Whether for high-purity water production or complex desalination needs, the PWM membrane ensures consistent, efficient operation and meets rigorous quality standards.

#
Model
Permeate flow GPD
Rejection Rate
Active Area ft2
Test Solution NaCl
1
Basic BW4040
2500
99.60%
85
2000 ppm NaCl 25C , pH: 7.5-8 , Testing Pressure: 225 psi, Recovery Rate : 15%
Basic BW8040
13000
99.50%
440
2000 ppm NaCl 25C , pH: 7.5-8 , Testing Pressure: 225 psi, Recovery Rate : 15%
Super BW4040
2900
99.50%
100
2000 ppm NaCl 25C , pH: 7.5-8 , Testing Pressure: 225 psi, Recovery Rate : 15%
2
ROD4040
2600
99.20%
90
500 ppm NaCl 25C , pH: 7.5-8 , Testing Pressure:100 psi, Recovery Rate : 15%
3
ROD8040
12500
99.50
440
500 ppm NaCl 25C , pH: 7.5-8 , Testing Pressure:100 psi, Recovery Rate : 15%
Max Operation pressure
Max Feed Flow Rate
Max Operating Temperature
pH Range, Continuous (operation)
pH Range, Continuous (short term cleaning)
Max Feedwater SDI (15 mins)
Max Free Chlorine Tolerance
Max Pressure drop (ΔP) for each element
1,200 psi (82.7 bar)
17 m3/h (8040), 3.6 m3/h(4040)
0-45 C
3-10
1-13
5
0.1 ppm
15 psi(0.1MPa)
bottom of page